A reproducible demonstration of detection, prioritization, and repair verification across 120 assets and six inspection campaigns.
Prepared by: Hadi Farahani, PhD
Demonstration project — synthetic operational data. This report demonstrates KANON's advanced applied industrial analytics methodology, validation architecture, and decision-support capabilities. It does not represent measured performance from an actual industrial facility.
Executive Technical Brief
v1.0 | SYNTHETIC
208.98
Summed Modeled Emission Rates (kg CH4/h)
4.59%
Undetected Rate Fraction (Modelled %)
6/6
Planted Events (54-100% CI)
85.7%
May Repair Effect (Efficiency)
The six highest-ranked simulated assets (ME-081, ME-082, ME-041, ME-002, ME-001, ME-042) are candidates for follow-up investigation. Field applicability remains unverified.
What this analysis does NOT establish: field-validated detection accuracy, verified abatement, or regulatory compliance.
KANON makes industrial measurement data reliable enough to support important decisions.
Q1 · Inspection priorities and detection uncertainty
If we only have limited inspection capacity, where should we look first — and how confident can we be that we're right?
Decision Dashboard
Targeted inspection of the six highest-ranked assets is a candidate strategy for evaluation under the modeled conditions.
208.98
Summed Modeled Emission Rates (kg/h)
4.59%
Undetected Rate Fraction (Modelled)
6/6
Planted Events Detected
336h
Median Detection Latency
Contents
⚠️
THE PROBLEM
Methane leaks are invisible, odorless, and financially material.
Operators must prioritize limited inspections despite imperfect detection.
A single missed high-rate source can dominate the annual emissions inventory.
Unmonitored leaks = unbudgeted liabilities.
⚙️
THE SOLUTION
A reproducible DuckDB analytical pipeline over six monthly inspection campaigns.
Priority ranking with quantified uncertainty bounds and confidence tiers.
Validation at event level, duration level, and out-of-sample.
Targeted inspection based on data, not guesswork.
✅
THE RESULT
All 6 planted leaks detected — recall 100%.
In this simulation, 4.59% of the summed inspection-level true emission rates occurred at nondetections. This is not a time-integrated methane mass estimate.
The reported decomposition attributes approximately 86% of the modeled May decline to efficiency effects rather than activity. Actual repair effectiveness is not established.
Documented synthetic evaluation and methodological limitations.
84.6%
Nondetections and emission-rate coverage. Nondetections represented 609 of 720 inspections (84.6%) and 4.59% of the summed modeled inspection-level true emission rates. These are rate statistics, not a time-integrated methane mass balance.
Key Definitions & Abbreviations LOD (Limit of Detection): The minimum source rate the sensor can reliably see. IQR / MAD: Interquartile Range and Median Absolute Deviation (robust statistical bounds). GUM: Guide to the Expression of Uncertainty in Measurement (ISO standard). DuckDB & Polars: In-process analytical database and high-speed DataFrame library used to process the 21,720 latent-rate records in milliseconds.
2 · Data Architecture
01
Industrial Data Sources
SCADA · Sensors · Throughput · Operational records
A: 120 assets (40 valves, 40 flanges, 40 compressors), 720 inspections across six monthly campaigns, 21,720 daily latent-rate records, and 6 planted leak events with repair on May 1.
Q: What is the detection method?
A: Sensor baseline with IQR/MAD anomaly detection. Detection probability follows a saturating exponential function: p = 1 − exp(−ln(2) · rate / scale), where scale grows with wind. Quantification error is log-normal with CV 0.25.
Q: What tools did we use?
A: The pipeline was built for speed and auditability. We used DuckDB as the analytical engine to join the truth and analyst schemas without loading everything into memory, and Polars for high-speed DataFrame manipulation. The entire 21,720-row dataset processes in under 2 seconds.
Q: What is the decomposition?
A: Total emissions = Activity × Emission Factor × (1 − Control Efficiency). Period-over-period change is split into an activity effect (which assets were inspected) and an efficiency effect (how much they leaked).
Figure 1 — Detection rate by asset type and wind condition. Flanges are systematically under-detected (4.5–5.0%) because their true rates are smallest.
4 · Validation
Q3 · Evaluation against planted events
Q: Did the method find the planted leaks?
A: Yes — recall 100% (6/6). However, with only 6 events, the 95% Clopper-Pearson lower bound is 54%. The wide interval reflects the small number of planted events. Shared simulation and inspection conditions also limit generalization.
Q: Why is precision 19.4%?
A: Precision against planted-event truth is 19.4%. However, the 25 detections were classified outside the planted-event catalog. These are not necessarily false physical detections. False-positive detections are excluded by the simulator assumption. Real-world precision and specificity are not established. We report both: the former tests the algorithm's alignment with the event catalog; the latter tests its behavior under the simulator assumptions.
Q: How fast do we detect a leak?
A: The recorded median latency was 336 hours (14 days). All planted events began on March 1 and the subsequent inspection occurred on March 15. This reflects the programmed scenario and schedule, not independently established field latency.
Figure 2 — Validation summary.
Event
Asset
Start
First detected
Latency
LEAK-01
ME-001
2025-03-01 12:00:00
2025-03-15 12:00:00
336 h
LEAK-02
ME-002
2025-03-01 12:00:00
2025-03-15 12:00:00
336 h
LEAK-03
ME-041
2025-03-01 12:00:00
2025-03-15 12:00:00
336 h
LEAK-04
ME-042
2025-03-01 12:00:00
2025-03-15 12:00:00
336 h
LEAK-05
ME-081
2025-03-01 12:00:00
2025-03-15 12:00:00
336 h
LEAK-06
ME-082
2025-03-01 12:00:00
2025-03-15 12:00:00
336 h
5 · The Business Case
Q4 · Illustrative economic sensitivity
Illustrative economic scenario: A continuous source of 30 kg CH4/h would emit 0.72 tonnes of methane per day. At an assumed GWP100 of 28 and USD 50/t CO2e carbon price, the hypothetical carbon-value exposure is USD 1,008/day. The USD 2,500/day blended-loss assumption is a scenario parameter, not a verified cost or regulatory penalty.
The ROI calculation (The "Targeted" Strategy)
The illustrative broad-inspection scenario uses a cost of USD 144,000; the targeted scenario uses USD 93,600. At an assumed benefit of USD 26,250 per avoided event, six avoided events would yield USD 157,500. If the accounting horizons are comparable, the targeted benefit-cost ratio is approximately 1.68. At least four avoided events are required to exceed its stated cost. Realized savings have not been established.
Figure 3b illustrates model-dependent break-even probabilities of approximately 59% at an assumed USD 2,500/day loss and 15% at USD 10,000/day. These are conditional scenario outputs, not validated investment recommendations.
Figure 3b — Illustrative break-even probability under the specified cost assumptions.
Does 17× cadence mean 17× detection?
No. Figure 3c shows that detection probability saturates. At ~15% per-visit detection, monthly catches 48%, weekly catches 94%. Faster cadence buys shorter latency, not infinite detection.
Figure 3c — Detection calibration. Probability saturates as cadence increases.
6 · Limitations
Q5 · Assumptions and limits of inference
Blind Spots Register — six substantive, quantified limitations.
L1 — Imperfect detection. Nondetections accounted for 84.6% of inspections and 4.59% of summed modeled inspection-level emission rates. This does not quantify missed methane mass.
L2 — Flanges are systematically under-detected. 4.5–5.0% detection rate vs. 27–28% for compressors. A field pilot would need to recalibrate the flange detection curve.
L3 — Asset-class differences. The reported nondetection fractions suggest variation between asset classes. Class-specific estimates require reconciliation against inspection-level modeled rates and must not be interpreted as integrated methane mass.
L4 — The simulator excludes false-positive physical detections by assumption. Detections outside the planted-event catalog are not necessarily false physical detections. Real-world specificity is not established.
L5 — Even 97.8%-probability sources can be missed. ME-001 on May 15 had detection probability 0.9783 and was not detected (uniform draw 0.9851). A single missed inspection is not proof of absence.
L6 — Nondetection is not zero. The blueprint states this explicitly; the data confirms it. A missed inspection is not a zero-emission observation.
Figure 4 — Ten simulated sources associated with higher undetected emission rates.
7 · Reproducibility
Q6 · Can a client re-run this analysis and verify the numbers?
Q: Can a client re-run the analysis?
A: The generator uses seed 1003, the database is constructed from six CSVs, and the six-step analytical chain is documented in reproducibility_chain.csv. Exact reproduction requires corresponding source versions, dependencies and reconciliation of historical manifest discrepancies.
Q: Can a client verify the numbers?
A: The historical reproducibility_manifest.csv records file fingerprints. Their evidential value depends on reconciliation with the corresponding files. Unresolved discrepancies prevent a claim of complete verification.
MASTER HASH (SHA-256 of all analytical outputs): a6b91c19ec2e8413e3b0f592cf18c1cc1388bb5e1ca953ea013cc277b88316cf
Source Data
9
Files fingerprinted
Analytical Scripts
6
Steps documented
Output Artifacts
17
CSVs generated
Audit Status
Historical manifest: 24/32 reconciled
Historical manifest: 6 exact matches, 18 CRLF-reconstructed matches, 7 unresolved hash mismatches and 1 untracked path. These results support provenance review but do not establish full reproducibility. The historical records remain documented in the project evidence files.
8 · Statement of Integrity
Statement of method integrity. This synthetic demonstration reports the documented methods, evaluation results and limitations. Historical file-hash discrepancies remain unresolved. The manifest supports provenance review, not complete reproducibility or independent scientific certification.
Conflict of Interest. This project was conducted independently as a methodological demonstration. No funding or analysis was influenced by equipment manufacturers or operators. This report does not claim regulatory compliance or field-validated performance.
9 · Decision Implications
Q7 · Operational implications
Q: What should we do Monday morning?
A: The modeled ranking identifies ME-081, ME-082, ME-041, ME-002, ME-001 and ME-042 as candidates for verification. Their reported priorities are 6–20 times those of the next tier under the stated ranking assumptions.
Q: How often should we inspect?
A: The modeled event duration permits 17 weekly, four monthly or one quarterly inspection opportunity. Additional visits may improve detection probability, but the relationship is nonlinear and depends on detection conditions and event persistence.
Q: Did the May repair work?
A: Approximately 86% of the modeled May decline is attributed to efficiency effects. Field repair effectiveness has not been independently established.
Q: How much methane are we still missing?
A: Nondetections account for 4.59% of the summed modeled true emission rates across inspection events. This is not a time-integrated methane mass estimate.
Q: What would change our answer?
A: The reported sensitivity scenarios indicate that a 20% wind-model perturbation changes mean detection probability by approximately 3 percentage points, while a 20% instrument-sensitivity perturbation has a larger effect. Field robustness requires independent assessment.
Figure 5 — Top 10 assets by median priority, with 95% uncertainty bounds.Figure 6 — Activity vs. efficiency decomposition. May repair is 85.7% efficiency.
Figure 7 — Detection latency, all events at 336 hours (14 days).
10 · References
IEA (2025) - Global Methane Tracker 2025. International Energy Agency, Paris.
European Commission (2024) - Regulation (EU) 2024/1787 on the reduction of methane emissions in the energy sector.
OGMP 2.0 (2025) - Oil and Gas Methane Partnership 2.0 Reporting Framework. UNEP.
US EPA (2024) - Standards of Performance for New, Reconstructed, and Modified Sources and Emissions Guidelines for Existing Sources: Oil and Natural Gas Sector Climate Review.
JCGM 100:2008 - Evaluation of measurement data: Guide to the expression of uncertainty in measurement (GUM).
ISO 8000-61:2016 - Data quality - Process reference model.